DigiElch Help

Window: Properties

Window: Properties

Previous topic Next topic  

Window: Properties

Previous topic Next topic  
<%EXTOGGLE%>Options

Option: Ru/Cd Correction

➢Ru (Ohm)
Add/remove uncompensated IR-drop to/from  the active experiment.

➢Cd (F)
Add/remove double layer capacity to/from  the active experiment.

Option: Displaying Impedance Data

➢Show
Controls whether the current curves of all simulations or only that of the active simulation are shown.

➢Use Thick Pen
Controls whether a thick or the default pen is used for drawing the current curve(s).

➢Connect Circles by Line
Controls whether the impedance data points (referring to the individual frequency components) are connected by line segments.

Option: Labels

➢X-Axis
Option for customizing the label on the x-axis.

➢Y-Axis
Option for customizing the label on the y-axis.

 

Option: Colors

➢Background
Option for customizing the color of the background on which the current curve is plotted.

➢Active Curve
Option for customizing the color with which the current curve of the active experiment is plotted.

➢Inactive Curve
Option for customizing the color with which the current curves of the inactive experiments are plotted.

➢Inactive Segments
Option for customizing the color with which the inactive segments of the active current curve are plotted.

➢Text
Option for customizing the color with which the min-max-info and some other text is plotted.

➢Labels
Option for customizing the color with which the axes are labeled.

 

Option: Font

➢Screen Font
Option for customizing the font used for plotting min/max-info and for labeling the axes on the screen display.

➢Printer Font
Option for customizing the font used for printing min/max-info and for labeling the axes.

 

Option: Export Data (*.txt)

➢Number Format
Controls whether numbers are exported to txt-files using comma (1,234) or point (1.234) format.

➢Separator
Selects  the separator used when exporting data to txt-files.

 

Option: Export to RAM-Disk

➢RAM-Disk Directory
The directory of the RAM-Disk to which the experiment is exported in use-file format.

 

Option: emf-Files

➢Save Black and White
Controls whether the image of the screen display is saved as Extended Meta File in the original screen colors or in "black on white".

 

Option: Import Data

➢Merge Files
Controls whether the existing (previously imported) CVs are merged with (or overwritten by) the imported ones.

➢Change Current Convention
Controls whether the imported current values are used "as they are" or multiplied by -1.
 

 

tipbulbModified Options will be saved in the Windows Registry and restored when restarting the program.

 

<%EXTOGGLE%>Summary: Play Movie

➢Option: Import Data
Watch video clip to see how the Import-Options can be customized.

 
Other options work analogously as shown in the video clip referring to the Tabbed Window: Simulations.